ATP-500 PON Power Meter

jw3213

Features:

  1. It can carry out synchronous measurement of voice, data and video signal in BPON/EPON/GPON.
  2. Providing simultaneous measurement for all three wavelengths in the fiber (1310nm, 1490nm, and 1550nm)
  3. Used in burst mode measurement of 1310nm upstream.
  4. Use the software to connect with PC, set the threshold, transfer data, and calibrate the wavelength.
  5. USB communication port enables data transfer to a PC. 1,000 measurement items can be saved in PON power meter or computer for data review.
  6. With optional OPM+VFL modules, including 850/1300/1310/1490/1550/1625nm of OPM module
  7. Optical power meter and VFL with one port.
  8. Offers up to 10 different threshold sets in total. Three status LEDs represent different optical signal conditions of Pass, Warn and Fail respectively.
  9. 10 minutes auto-off function can be activated or deactivated.
  10. Good key design, high sensitivity, greatly reducing the volume and weight of the tester.
  11. Different models corresponding to different function, according to own use to choose.

PON Power Meter Specification:

1310nm Upstream Measurement:
Pass Zone 1260nm~1360nm
Measurement Range -40dBm~+10dBm
Input Power (max) 15dBm
Isolation @ 1490/1550 >40dB
Burst Mode Measurement Error <±0.5dB
1490nm Downstream Measurement:
Pass Zone 1470nm~1505nm
Measurement Range -40dBm~+10dBm
Input Power (max) 15dBm
Isolation@1310/1550(dB) >40dB
1550 Downstream Measurement:
Pass Zone 1535nm~1570nm
Measurement Range -40dBm~+10dBm
Output Power (max) 25dBm
Isolation @ (1310/1490nm) >40dB
Measurement Accuracy:
Connatural Uncertainty ±0.5dB
Linearity ±0.1dB
Passing Through Insertion Loss <1.5dB
General Information:
Detector Type InGaAs
Optical Connector FC/SC/ST Interchangeable/2.5 universal adapter
Fiber Type SM 9/125um
Measurement Unit dB/dBm/xW
Resolution 0.01dB
Operation Voltage DC 3.3V~5.5V
Power Supply 3pc*1.5V battery
Continuously Operation Time PON: 90h; OPM:100h; VFL: 50h
Operation Temperature -10℃~60℃
Storage Temperature -25℃~70℃
Net Weight 424g
Standard Accessories:
FC/PC adapters, SC/PC adapters, 3*AA rechargeable batteries, USB cable, test report, carrying bag, CD software, user manual
Customization:
FC/APC adapters, SC/APC adapters

Note: The operation time of the battery are all for the instrument that do not turn on backlight, if the backlight turn on the operation time will be shorted.

PM Module (Power Meter, as optional function):

Measurement Accuracy:
Connatural uncertainty ±0.5dB
Linearity ±0.1dB
Measurement Range -70dBm~+6dBm
General Information:
Measurement Unit dB/dBm
Resolution 0.01dB
Calibration Wavelength 1310/1490/1550/1625nm
Detector Type InGaAs
Optical Connector FC/SC/ST Interchangeable/2.5 universal adapter

VFL Module (Visual Fault Locator, as optional function):

Output power >0.5mW
Wavelength 650nm
Optical Connector FC/SC/ST Interchangeable/2.5 universal adapter
Fiber Type SM/MM

Ordering Information:

Model Name Optional Function
ATP-500 PON Power Meter SC/PC and FC/PC, without OPM or VFL
ATP-500A PON Power Meter SC/APC and FC/APC, without OPM or VFL
ATP-500V PON Power Meter SC/PC and FC/PC, with VFL
ATP-500P PON Power Meter SC/PC and FC/PC, with OPM
ATP-500VP PON Power Meter SC/PC and FC/PC, with OPM and VFL